Outstanding Features

  • LCD Panel
  • Cold Start
  • DSP, IGBT,PFC Technology
  • Green and Environment-Friendly
  • 0.8 Load Power Factor for 4 Years
  • Intelligent LCD Display (Optional)
  • Automatic Recharge Even UPS is Off
  • Intelligent Battery Management (IBM)
  • Beeping Alarm on Battery, Battery Low and Overload
  • Automatic Adjustment to 50Hz/60Hz Power Supply System
  • Strong Expansion Function,Webpower,AS400,RS485 Card could be Installed

Online UPS



Technical Specification:
Model
C1K
C1K
C1K
C1K
C1K
C1K
Rated Power
1000VA / 800W
2000VA / 1600W
3000VA / 2400W
AC Input
Battery Input
AC Output
Panel Display
Interface
Power Outlets
Function
Environment
Physical
Input System
Range Voltage
Frequency
Voltage Range
Frequency Range
Power Factor
Voltage Range of Bypass
Type
Voltage Range of Battery
Bat Number
Inside Batteries
Backup Time
Charging Current
Battery Charged Time
Output System
Output Voltage
Output Frequency
Dynamic Voltage Transient Range
Dynamic Transient Restore
Waveform
Power Factor
Overload Capability
Current Peak Coefficient
Transfer Time
Efficiency
THD
LCD and LED
Communications
Numbers and Types
Cold start
Automatic Charge
Automatic Restart
Frequency
Alarm
Protection
Temperature
Noise level
Humidity
Weight (KGs)
Shipping Weight
Net Dimensions (L*W*Hmm)
Gross Dimensions L*W*Hmm)
Single Phrase & Earth Ground
210 / 220 / 230Vac
50 / 60Hz
115 ~ 300VAC ± 5@Half Load; 176 - 296VAC ± 5@Full Load
45~55Hz ± 0.5Hz or 55~65Hz ± 0.5Hz Auto Sense
0.99
65VAC × (1±5%) ~ 280VAC × (1±5%)
Lead-Acid maintenance-free
36VDC(24V/48V optional)
72VDC(48V/96V optional)
96VDC(48V/72V optional)
3 (2/4 optional)
6 (4 /8 optional)
8 (4/6 optional)
12V7AH
12V7AH
12V7AH
Standard UPS: Half loaded ≥ 10minutes, Full loaded ≥ 5minutes.
Long Backup UPS: Depend On The External Batteries
1A
7A
1A
7A
1A
7A
Standard UPS: 5 hrs to 90% battery capacity. Long Backup UPS: Depend On The Capacity of External Batteries
Single Phrase & Earth Ground
210 / 220 / 230Vac ± 2%
50 ± 5Hz (line normal, according to line) 50Hz ± 1% (line abnormal)
<5%
< 60ms
True Sine Wave
0.8
105 ~ 125% ≥ 60s,126 ~ 150% ≥3 0s The Recovery Point is 90%
3:1
0ms (AC to DC) and < 4ms (AC to Bypass)
85%
88%
<2% full load(linear load)
I/P Voltage, I/P & Frequency,Battery Voltage,UPS Status, Load, Temperature, O/P Voltage,Frequency, B/P Voltage,Frequency
RS232,Intelligent Slot (Web power card, or As400 Card Optional),Dry Contacts Optional
2 SOCKETS
4 SOCKETS
3 SOCKETS and 1 Terminal
DC Power On
Automatic Charge When UPS is Off
Automatic Restart If Main Power Coming After Battery Mode Shutdown
50HZ / 60HZ Auto Adjustable
AC / DC Input Under Bbnormal ,Overload Condition and Inverter Problems
AC Input or Output Above or Below The Range of Voltage Overload ,Over Temperature and Short Circuit Protection
-5 to 45 Degree
≤5 5dB
20% to 90%
11.5
5.5
22
10
27
11
12.5
6.6
24.5
12.5
29.5
13.5
345 * 145 * 230
420 * 190 * 335
430 * 240 * 340
550 * 350 * 490

All Rights Reserved To Tecmax Electonics, Bangalore.